|
|
|
|
LEADER |
04126nam a22006255i 4500 |
001 |
978-981-287-969-1 |
003 |
DE-He213 |
005 |
20210616063908.0 |
007 |
cr nn 008mamaa |
008 |
160105s2016 si | s |||| 0|eng d |
020 |
|
|
|a 9789812879691
|9 978-981-287-969-1
|
024 |
7 |
|
|a 10.1007/978-981-287-969-1
|2 doi
|
050 |
|
4 |
|a R856-857
|
050 |
|
4 |
|a HC79.E5
|
050 |
|
4 |
|a GE220
|
072 |
|
7 |
|a MQW
|2 bicssc
|
072 |
|
7 |
|a TEC059000
|2 bisacsh
|
072 |
|
7 |
|a MQW
|2 thema
|
082 |
0 |
4 |
|a 610.28
|2 23
|
100 |
1 |
|
|a Mughal, Yar M.
|e author.
|4 aut
|4 http://id.loc.gov/vocabulary/relators/aut
|
245 |
1 |
2 |
|a A Parametric Framework for Modelling of Bioelectrical Signals
|h [electronic resource] /
|c by Yar M. Mughal.
|
250 |
|
|
|a 1st ed. 2016.
|
264 |
|
1 |
|a Singapore :
|b Springer Singapore :
|b Imprint: Springer,
|c 2016.
|
300 |
|
|
|a XV, 81 p. 42 illus., 5 illus. in color.
|b online resource.
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
347 |
|
|
|a text file
|b PDF
|2 rda
|
490 |
1 |
|
|a Series in BioEngineering,
|x 2196-8861
|
505 |
0 |
|
|a Introduction and Motivation -- State of the Art of Modelling and Simulation of the Physiological Systems -- Proposed Novel Generic Framework for Modelling the Bioelectrical Information -- Implementation of the Framework and the Experimental Results -- Conclusions.
|
520 |
|
|
|a This book examines non-invasive, electrical-based methods for disease diagnosis and assessment of heart function. In particular, a formalized signal model is proposed since this offers several advantages over methods that rely on measured data alone. By using a formalized representation, the parameters of the signal model can be easily manipulated and/or modified, thus providing mechanisms that allow researchers to reproduce and control such signals. In addition, having such a formalized signal model makes it possible to develop computer tools that can be used for manipulating and understanding how signal changes result from various heart conditions, as well as for generating input signals for experimenting with and evaluating the performance of e.g. signal extraction methods. The work focuses on bioelectrical information, particularly electrical bio-impedance (EBI). Once the EBI has been measured, the corresponding signals have to be modelled for analysis. This requires a structured approach in order to move from real measured data to the model of the corresponding signals. This book proposes a generic framework for this procedure. It can be used as a guide for modelling impedance cardiography (ICG) and impedance respirography (IRG) signals, as well as for developing the corresponding bio-impedance signal simulator (BISS).
|
650 |
|
0 |
|a Biomedical engineering.
|
650 |
|
0 |
|a Cardiac imaging.
|
650 |
|
0 |
|a Medical physics.
|
650 |
|
0 |
|a Radiation.
|
650 |
|
0 |
|a Signal processing.
|
650 |
|
0 |
|a Image processing.
|
650 |
|
0 |
|a Speech processing systems.
|
650 |
|
0 |
|a Respiratory organs—Diseases.
|
650 |
1 |
4 |
|a Biomedical Engineering and Bioengineering.
|0 https://scigraph.springernature.com/ontologies/product-market-codes/T2700X
|
650 |
2 |
4 |
|a Cardiac Imaging.
|0 https://scigraph.springernature.com/ontologies/product-market-codes/H29071
|
650 |
2 |
4 |
|a Medical and Radiation Physics.
|0 https://scigraph.springernature.com/ontologies/product-market-codes/P27060
|
650 |
2 |
4 |
|a Signal, Image and Speech Processing.
|0 https://scigraph.springernature.com/ontologies/product-market-codes/T24051
|
650 |
2 |
4 |
|a Pneumology/Respiratory System.
|0 https://scigraph.springernature.com/ontologies/product-market-codes/H33134
|
710 |
2 |
|
|a SpringerLink (Online service)
|
773 |
0 |
|
|t Springer Nature eBook
|
776 |
0 |
8 |
|i Printed edition:
|z 9789812879684
|
776 |
0 |
8 |
|i Printed edition:
|z 9789812879707
|
776 |
0 |
8 |
|i Printed edition:
|z 9789811357350
|
830 |
|
0 |
|a Series in BioEngineering,
|x 2196-8861
|
856 |
4 |
0 |
|u https://doi.org/10.1007/978-981-287-969-1
|
912 |
|
|
|a ZDB-2-ENG
|
912 |
|
|
|a ZDB-2-SXE
|
950 |
|
|
|a Engineering (SpringerNature-11647)
|
950 |
|
|
|a Engineering (R0) (SpringerNature-43712)
|